The EDGE EVO Door and Reader module is designed for interfacing with the EDGE EVO Hi-O Networked Controller to electronic door
components and a traditional Wiegand reader.
Designed for providing interface to traditional discrete access inputs and outputs, the Door component provides four analog/digital inputs
and two outputs. Congure the Door component in two ways; as a primary door interface to REX, Door Position Switch, Battery Fail, Power
Fail, Lock, and Aux (Group 1) or as a general purpose input/output module (Group 2).
Congure the Reader Module in two ways, either a Group 1 or Group 2 device. When two readers are present at one access control point,
the secure reader side is assigned Group 1.
Specifications
Door Module
CONDITIONS
VOLTAGE DC
(VDC)
CURRENT
(Amp)
POWER
(W)
OPERATING
TEMPERTURE
CABLE LENGTH
UL REF
NUMBER
Input
DC Input (NSC)
+12 VDC 0.04 Amp 0.48
32° - 122°F
(0° - 50° C)
Inputs = 500 ft (150 m)
Outputs = 500 ft (150 m)
Hi-O CAN Bus Total Length 100 ft (30 m) -
22 AWG ● 0.65mm ● 0.33mm
2
Maximum between drops 30 ft (10 m)
22 AWG ● 0.65mm ● 0.33mm
2
MEDMAxNN
x = K for Black
G for Grey
+24 VDC 0.04 Amp 0.96
DC Input (MAX)
+12 VDC 0.80 Amp 9.6
+24 VDC 0.80 Amp 19.2
Supervised inputs
(AC, Batt, REX, Door Mon) (MAX)
0-5 VDC
Reference
0.005 Amp
(Sink)
0.025
Output
Strike *** /
AUX
NC or NO
DC Output
(MAX)
AUX 12 VDC
Input @
Controller
Unregulated (Wet)
Jumpers
+10 to +12 VDC 0.70 Amp* 8.40
AUX 24VDC
Input @
Controller
Unregulated (Wet)
Jumpers
+23 to +24 VDC 0.70 Amp* 16.80
Regulated (Wet)
Jumpers – 12 VDC
+10 to +12 VDC 0.70 Amp* 8.40
PoE Input @
Controller
Unregulated (Wet)
Jumpers
+16.5 to 24 VDC 0.30 Amp* 7.2
Regulated (Wet)
Jumpers – 12 VDC
+10 to +12 VDC 0.50 Amp* 6.0
AUX 12-24 VDC
/ PoE Input @
Controller
Jumpers Set to Dry
+12 to 24 VDC
External
2.00 Amp** 24.00
Reader Module
CONDITIONS VOLTAGE DC (VDC)
CURRENT
(Amp)
POWER
(W)
OPERATING
TEMPERTURE
CABLE LENGTH
UL REF
NUMBER
Input
DC Input (NSC)
+12 VDC
0.03 Amp
0.36
32° - 122°F
(0° - 50° C)
Wiegand = 500 ft (152.4 m) - 22 AWG ● 0.65mm ● 0.33mm
2
MEWMAxNN
x = K for Black
G for Grey
+24 VDC 0.72
DC Input (MAX)
+12 VDC
0.70 Amp
8.4
+24 VDC 16.8
Data 1/CLK , Data 0/Data (MAX) 0-5 VDC Reference N/A N/A
Output
Reader PWR
Output VDC
(MAX)
AUX 12 VDC
@ Controller
+9.8 to +12.25 VDC
0.30 Amp* 3.67
AUX 24 VDC
@ Controller
0.60 Amp* 7.35
PoE Input @
Controller
0.50 Amp* 6.12
GRN LED, RED LED,
Beep and Hold (MAX)
0-5 VDC Reference
0.005 Amp
(sink)
0.025
External Tamper - (MAX) +5 VDC (NOM) 0.017Amp 0.085
NSC = Normal Standby Condition ** Each Relay
* Combined output rating not to exceed V*I = W *** Shared between relays
1.2 Amp (+24VDC AUX Input, 28.8 W)
1.2 Amp (+12VDC AUX Input, 12.96 W)
EDGE EVO
®
Door & Reader Module
EDWM-M
InstallatIon GuIde
82363-901, Rev C.1
December 2012
© 2009 - 2012 HID Global Corporation. All rights reserved.
15370 Barranca Parkway
Irvine, CA 92618-2215
USA
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - EDGE EVO

The EDGE EVO Door and Reader module is designed for interfacing with the EDGE EVO Hi-O Networked Controller to electronic door components and a tradit

Page 2 - 1 Wiring

Door / Reader Module EDWM-M82363-901 C.1 INSTALLATION GUIDE2©2009 - 2012 HID Global Corporation. All rights reserved.1 WiringGNDCAN_HCAN_L(12 VDC or 2

Page 3 - Door / Reader Module

82363-901 C.1INSTALLATION GUIDE3©2009 - 2012 HID Global Corporation. All rights reserved.Door / Reader Module EDWM-M1.3 Tamper (Reader Interface Boar

Page 4 - HID Global

RegulatoryULConnect only to a Listed Access Control / Burglary power-limited power supply, or Listed Access Control / Burglary PoE (Power-over-Etherne

Commentaires sur ces manuels

Pas de commentaire